Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.18.8.(1) | Application | Intent |
+ |
Application | Application 1: Fire alarm systems in storage
garages conforming to Article 3.2.2.83. [open-air storage
garages ], where there are no other occupancies in
the building. This applies
to buildings which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
|
Top of Page | |
Intent | Intent 1: To exempt open-air storage garages from the application
of Sentence 9.10.18.2.(1), which might otherwise require a fire alarm
system, on the basis that there are no other occupancies in the building [thus
minimizing fire risks], the construction is noncombustible and the storeys
are open-air. |