Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.19.3.(2)
+
Application
Application 1: 
Battery operated smoke alarms [installed in dwelling units and sleeping rooms not within dwelling units ], where the building is not supplied with electrical power.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To exempt certain buildings from the requirements of Sentence 9.10.19.3.(1), which would otherwise require smoke alarms to be installed with permanent connections to an electrical circuit, on the basis that such buildings are not supplied with electrical power and battery-operated smoke alarms will provide an acceptable level of performance in such circumstances.