Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.21.1.(1)
+
Application
Application 1: 
Fire protection for construction camps to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in:
  • Sentence 9.10.21.2.(1), which applies to the separation of construction camp sleeping rooms not within dwelling units,
  • Sentence 9.10.21.3.(1), which applies to the separation of construction camp floor assemblies between the first storey and the second storey, other than in dwelling units,
  • Sentence 9.10.21.4.(1), which applies to the separation of walkways of combustible construction connecting buildings,
  • Sentence 9.10.21.5.(1), which applies to spatial separation of construction camp buildings,
  • Sentence 9.10.21.6.(1), which applies to surface flame-spread ratings of wall and ceiling surfaces, other than doors and in dwelling units,
  • Sentence 9.10.21.6.(2), which applies to corridors providing access to exit from sleeping rooms and having a fire-resistance rating of not less than 45 min, other than in dwelling units,
  • Sentence 9.10.21.7.(1), which applies to smoke detectors in corridors providing access to exit from sleeping rooms in construction camp buildings with sleeping accommodation for more than 10 persons, other than in dwelling units,
  • Sentence 9.10.21.8.(1), which applies to portable fire extinguishers in construction camp buildings, and
  • Sentence 9.10.21.9.(1), which applies to hose stations in construction camp buildings providing sleeping accommodation for more than 30 persons.
Top of Page
Intent
Intent 1: 
To clarify that the more specific requirements in Subsection 9.10.21. are intended to supersede anything else in Section 9.10. in cases of conflict.
Intent 2: 
To direct Code users to Subsections 9.10.1. to 9.10.19.