Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.21.2.(1) | Application | Intent |
OS1 | + | OP1 |
Application | Application 1: Minimum fire-resistance rating of fire separations that separate sleeping rooms within dwelling units in construction camps from each other
and from the remainder of the building.
This applies to construction camps to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
|
Top of Page | |
Intent | Intent 1: To exempt sleeping rooms within dwelling units from the
requirement in the latter part of Sentence 9.10.21.2.(1) for a minimum 30
min rated separation, on the basis that the sleeping rooms are equipped
with smoke alarms and have a small occupant load, which should enable persons
to quickly escape in the early stages of a fire. |