Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.21.4.(1)
OS1OP1OP3
ObjectiveOP1 Fire Protection of the Building
Attribution
Application
Application 1: 
Minimum fire-resistance rating of fire separations that separate walkways from each building, where the walkways :
This applies to construction camps to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability that fire will spread from an adjacent building to the [connected] building by means of a walkway, which could lead to damage to the building.
Top of Page