Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.21.6.(2) | Application | Intent |
+ | + |
Application | Application 1: Maximum surface flame-spread
rating of corridors in dwelling units that:
This applies to construction camps to which
Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
|
Top of Page | |
Intent | Intent 1: To exempt the surfaces of corridors within dwelling units
from the requirement in the latter part of Sentence 9.10.21.6.(2) for
a certain maximum flame-spread rating, on the basis that the dwelling units
are equipped with smoke alarms and have a small occupant load, which should
enable persons to quickly escape in the early stages of a fire.
|
Top of Page |