Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.22.3.(2) | Application | Intent |
+ |
Application | Application 1: Protection, as described in Sentence 9.10.22.3.(1),
of countertop splash boards or back plates that extend above the level of
heating elements or burners of gas or electric ranges.
This applies to buildings to which Part
9 applies [see Sentence 1.3.3.3.(1) of Division A for application of
Part 9].
|
Top of Page | |
Intent | Intent 1: To supersede the requirements of Sentence 9.10.22.3.(1) and
not require a protective covering, on the basis that the construction and
location of such countertop elements are such that the elements are not expected
to be ignited by range burners or elements. Intent 2: To supersede the requirements stated in CSA B149.1, referred
to in Sentence 9.10.22.1.(1), with regard to natural gas ranges, in cases
of conflict. |