Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.13.2.1.(2)
OH1OS2
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Dampproofing of floors-on-ground, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in:
  • Sentence 9.13.2.1.(3), which applies to
    • floors in garages,
    • floors in unenclosed portions of buildings, and
    • floors installed over not less than 100 mm of coarse clean granular fill in conformance with Article 9.16.2.1., and
  • Sentence 9.13.3.1.(1), which applies to walls and floors that are subject to hydrostatic pressure.
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate resistance to moisture transfer from the ground, which could lead to the ingress of moisture from the ground.
This is to limit the probability of:
  • compromised thermal performance of components intended to provide resistance to heat transfer, which could lead to an inadequate control of the temperature of interior spaces,
  • water accumulation or an inadequate control of relative humidity,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of elements supported by the floors-on-ground.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.