Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.14.3.3.(4) | Application | Intent |
OH1 | OS2 | OP2 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Granular material used to cover drain tiles and drain
pipes that are installed at the bottom of exterior foundation walls
of buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions:
except:
|
Top of Page | |
Intent | Intent 1: To limit the probability of inadequate percolation down
to drain tiles or pipes, which could lead to silting-up, which could lead
to excessive moisture loading on foundation walls and basement floors.
This is to limit the probability of the accumulation of water under
hydrostatic pressure, which could lead to:
This is to limit the probability of harm to persons.
Intent 2: To limit the probability of inadequate percolation down
to drain tiles or pipes, which could lead to silting-up, which could lead
to excessive moisture loading on the soil immediately beneath the footings,
which could lead to saturation and a reduction in the soil's bearing capacity,
which could lead to the failure of foundation walls and basement floors, which
could lead to harm to persons. |