Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.14.5.2.(1)
OH1OS2OP2OS3
ObjectiveOP2 Structural Sufficiency of the Building
Attribution
(a),(b) [F60,F61-OP2.3,OP2.4]
(c) [F52-OP2.3]
Application
Application 1: 
Sump pits without pumps, for foundation drains for buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of:
  • [Clauses (a) and (b)] silting-up of the sump pit, which could lead to the ingress of moisture from the ground, or
  • [Clause (c)] excessive moisture transfer from the sump pit into interior spaces, which could lead to high relative humidity.
This is to limit the probability of:
  • compromised structural integrity of foundation walls and basement floors, or of elements supported by the walls or floors, or
  • deterioration, which could lead to compromised integrity of elements supported or protected by exterior foundation walls.
This is to limit the probability of:
  • the space being unsuitable for its intended use, or
  • damage to the building.
Top of Page