Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.14.5.2.(3) | Application | Intent |
OH1 | OS2 | OP2 |
Objective | OP2 Structural Sufficiency of the Building |
Attribution | |
Application | Application 1: Provision of automatic pumps for sump pits, where
gravity drainage is not practical, for foundation drains
for buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]. |
Top of Page | |
Intent | Intent 1: To limit the probability of excessive moisture loading on
foundation walls and basement floors, which could lead to:
This is to limit the probability of:
This is to limit the probability of:
Intent 2: To limit the probability of excessive moisture loading on
the soil immediately beneath the footings, which could lead to saturation
and a reduction in the soil's bearing capacity, which could lead to the failure
of foundation walls and basement floors, which could lead to damage to the
building. |