Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.14.6.4.(1)
OH1OS2OP2OS3
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Catch basins in driveways of buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of the inadequate drainage of water from driveways, which could lead to the ingress of water into garages, which could lead to:
  • an inadequate control of the temperature of interior spaces, relative humidity, or water ingress and accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of elements protected by the environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.
Top of Page