Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.15.2.1.(1)
+
Application
Application 1: 
Concrete for foundation walls and footings, for buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where the foundation walls and footings are:
  • not subject to surcharge, and
  • erected on stable soils with
    • for standard foundation construction and for buildings of wood-frame construction [see Article 9.23.1.1.] or masonry construction, an allowable bearing pressure of 75 kPa or greater, and
    • for flat insulating concrete form foundation walls and for buildings of light-frame construction [see Article 9.4.2.1.] or flat insulating concrete form construction that are not more than 2 storeys in building height, with a maximum floor-to-floor height of 3 m, and contain only a single dwelling unit, an allowable bearing pressure of 100 kPa or greater.
Exceptions: 
except as stated in Sentence 9.15.1.2.(1), which applies to foundations and footings for buildings erected on permafrost.
Top of Page
Intent
Intent 1: 
To direct Code users to Section 9.3., which contains requirements regarding concrete.