Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.15.3.3.(2)
+
Application
Application 1: 
Design of concrete footings for foundations for buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where the span of supported joists exceeds 4.9 m, the foundations are not subject to surcharge, and:
  • the footings support
    • foundation walls of masonry, concrete, or flat insulating concrete form walls
    • above-ground walls of masonry, flat insulating concrete form walls or light wood-frame construction, and
    • floors and roofs of light wood-frame construction [see Article 9.4.2.1.], and
  • the specified live load on any floor supported by the footings does not exceed 2.4 kPa.
Exceptions: 
except as stated in:
  • Sentence 9.15.1.2.(1), which applies to foundations and footings for buildings erected on permafrost, and
  • Sentence 9.15.3.4.(2), which applies to joist spans exceeding 4.9 m in buildings with light wood-frame walls, floors and roofs.
Top of Page
Intent
Intent 1: 
To expand the application of Section 4.2. to include Part 9 buildings where the span of supported joists exceeds the application of Table 9.15.3.4. and the criteria of Sentence 9.15.3.4.(2).