Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.15.5.2.(1)
OS2OP2OH1OH4OS3
ObjectiveOS2 Structural Safety
Attribution
[F20-OS2.3] Applies to elements that support or are part of an environmental separator.
Application
Application 1: 
Beams supported on foundation walls of masonry units, on soils having an allowable bearing pressure of 75 kPa or greater, for buildings of wood-frame or masonry construction to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.15.1.2.(1), which applies to buildings that are erected on permafrost.
Top of Page
Intent
Intent 1: 
To limit the probability of:
  • an inadequate resistance to concentrated loads imposed by beams, which could lead to the compressive failure of masonry units, which could lead to the structural failure of the masonry [see corresponding requirement in Sentence 9.20.8.4.(2)], or
  • an excessively narrow contact area between beams and hollow masonry, which could lead to wood fibres being crushed, which could lead to the structural failure of beams.
This is to limit the probability of compromised structural integrity, which could lead to:
  • structural failure, or
  • where elements support or are part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to the deterioration of building elements.
This is to limit the probability of harm to persons.