Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.15.6.2.(1)
OH1OS2OP2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Exterior surfaces of concrete block foundation walls that are above ground level on soils having an allowable bearing pressure of 75 kPa or greater, for buildings of wood-frame or masonry construction to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.15.1.2.(1), which applies to buildings that are erected on permafrost.
Top of Page
Intent
Intent 1: 
To limit the probability of excessively porous mortar between concrete blocks, which could lead to an inadequate resistance to water, which could lead to the ingress of surface or rainwater, which could lead to deterioration, which could lead to compromised integrity of elements supported or protected by foundations, which could lead to harm to persons.
Top of Page