Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.16.2.1.(1)
OH1OS2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Minimum depth and maximum diameter for granular material beneath floors supported on ground or on granular fill, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except:
  • as stated in Sentence 9.16.2.1.(2), which applies to floors in garages, carports or accessory buildings,
  • for unenclosed spaces, and
  • where floors are waterproofed.
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate drainage layer beneath floors-on-ground, which could lead to the ingress of moisture from the ground, which could lead to the deterioration, which could lead to compromised structural integrity of floors-on-ground or of elements protected by floors on ground, which could lead to harm to persons.
Top of Page