Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.16.3.1.(1)
OH1OS2OS3
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Grading or drainage for floors supported on ground or on granular fill which do not provide structural support for the superstructure, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except:
  • as stated in Sentence 9.16.3.2.(1), which applies to a floor-on-ground where groundwater levels may cause hydrostatic pressure beneath the floor-on-ground, and
  • where protection against the ingress of water under the floor can be shown to be unnecessary.
Top of Page
Intent
Intent 1: 
To limit the probability of excessive moisture loading on floors-on-ground, which could lead to compromised structural integrity of floors-on-ground, which could lead to the ingress of moisture from the ground, which could lead to the deterioration of building elements, which could lead to harm to persons.