Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.16.4.2.(1)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Topping courses on cast-in-place concrete floor slabs supported on ground or on granular fill which do not provide structural support for the superstructure, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of:
  • an inadequate compressive strength of concrete topping,
  • an inadequate hardness, and
  • excessive deterioration over time.
This is to limit the probability of uneven walking surfaces, which could lead to persons tripping or falling, which could lead to harm to persons.