This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.17.3.1.(1) | Application | Intent |
OS2 | OP2 | OH1 | OH4 | OS3 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Minimum size for steel pipe columns, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9], that are used to support:
Exceptions:
except as stated in Sentence 9.17.3.1.(2), which applies to
columns that have an outside diameter of less than 73 mm and/or
a wall thickness of less than 4.76 mm, where the loadbearing capacity
has been shown to be adequate.
|
Top of Page | |
Intent | Intent 1: To limit the probability that columns will be unable to
resist expected gravity loads transmitted through beams, which could lead
to the structural failure of columns. This is to limit
the probability of compromised structural integrity, which could lead to:
This is to limit the probability of harm to persons.
|
Top of Page |