Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.18.7.1.(4) | Application | Intent |
OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Noncombustible register
protection for crawl spaces whose exterior walls have less than 25% of their
total area above exterior ground level open to the outdoors, that are under
1-storey portions of dwelling
units and are used as warm-air plenums, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]. |
Top of Page | |
Intent | Intent 1: To limit the probability that debris, such as smouldering
cigarette butts, will fall through the floor register outside the protected
area and lead to the ignition of combustible materials in the crawl space
plenum, which could lead to harm to persons. |