Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.19.1.2.(1)
OH1OS2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Vent areas for attic or roof spaces, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where:
  • insulation is installed above the ceiling and below the roof sheathing,
  • the roof slope is 1 in 6 or greater, and
  • the roof is not constructed with roof joists.
Exceptions: 
except:
  • where attic or roof space venting can be shown to be unnecessary, and
  • as stated in Sentence 9.19.1.4.(1), which applies to the lower portions of mansard or gambrel roofs.
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate vent area for roofs, which could lead to:
  • condensation,
  • the accumulation of moisture, or
  • the formation of ice dams.
This is to limit the probability of deterioration, which could lead to compromised structural integrity of attic or roof assemblies or of elements protected by attic or roof assemblies, which could lead to harm to persons.