Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.19.2.1.(3)
OH1OS2OH2
ObjectiveOH1 Indoor Conditions
Attribution
[F42-OH1.1] [F61-OH1.1,OH1.2,OH1.3] Applies where access is from the exterior.
[F42-OH1.1] Applies where access is from an unheated enclosed space.
[F51-OH1.2] Applies where access is from an interior heated space.
Application
Application 1: 
Closures for access hatches to attic or roof spaces that measure:
  • not less than 3 m2 in area,
  • not less than 1 m in length or width, and
  • not less than 600 mm in height over an area that is not less than 3 m2 and not less than 1 m in length or width.
This applies where access to attic or roof spaces is:
  • from the exterior,
  • from interior heated space, or
  • from unheated enclosed space (e.g. garage).
This applies in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of openings in environmental separators, which could lead to:
  • the ingress of precipitation,
  • the ingress of insects or vermin,
  • excessive heat transfer,
  • condensation,
  • the accumulation of moisture or the ingress of water backed up by ice dams,
  • drafts, or
  • the ingress of pollutants from adjacent attic or roof spaces.
This is to limit the probability of:
  • compromised thermal performance of components intended to provide resistance to heat transfer, which could lead to an inadequate control of the temperature of interior spaces or relative humidity,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting,
  • deterioration, which could lead to compromised integrity of ceilings acting as environmental separators, or
  • water accumulation in interior spaces.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.