Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.20.5.2.(2)
OH1OS2OP2OS1
ObjectiveOS2 Structural Safety
Attribution
[F20,F22-OS2.3] Applies to elements that support or are part of an environmental separator.
Application
Application 1: 
Steel angle lintels supporting masonry veneer over openings, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • where the wall height does not exceed 11 m in height above the foundation wall, and
  • in which the roof or floor system above the first storey is not of concrete construction.
Top of Page
Intent
Intent 1: 
To limit the probability of:
  • lintels that are inadequate in size or have an excessive span, which could lead to the excessive deflection or failure of lintels, which could lead to the cracking or structural failure of masonry veneer over openings, or
  • an inadequate bearing area between lintels and supported masonry veneer, which could lead to shear or compression failure of masonry veneer.
This is to limit the probability of:
  • masonry falling from the building, or
  • where masonry construction is part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to compromised structural integrity, which could lead to structural collapse.
This is to limit the probability of harm to persons.