Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.20.6.5.(1)
OS2OP2OH1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Maximum height of unreinforced and nominally reinforced masonry parapet walls, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • where the wall height above the foundation wall does not exceed 11 m, and
  • in which the roof or floor system above the first storey is not of concrete construction.
Exceptions: 
except as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry is designed for specified loads on the basis of ultimate and serviceability limit states.
Top of Page
Intent
Intent 1: 
To limit the probability of an excessively high height-to-thickness ratio, which could lead to an inadequate resistance to expected wind loads.
This is to limit the probability of cracking of masonry or mortar, which could lead to excessive moisture transfer, which could lead to:
  • precipitation ingress, or
  • compromised thermal performance of components intended to resist heat transfer.
This is to limit the probability of:
  • an inadequate control of temperatures in interior spaces, drafts, relative humidity or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to further compromised integrity of environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.