This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.20.9.4.(5) | Application | Intent |
OH1 | OS2 | OP2 | OS1 | OH4 | OS3 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Filling the space between wythes that are tied together
with rod-type metal ties, in above-ground masonry walls that consist of 2
or more wythes, in buildings to which Part 9 applies
[see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
Exceptions:
except:
|
Top of Page | |
Intent | Intent 1: To limit the probability of inadequate support for ties,
which could lead to the excessive flexing of ties under lateral loads, which
could lead to inadequate load distribution among the wythes of multiple-wythe
masonry walls, which could lead to an inability to resist transverse or vertical
loads, which could lead to cracking or buckling. This
is to limit the probability of compromised structural integrity, which could
lead to:
This is to limit the probability of harm to persons.
|
Top of Page |