Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.20.11.1.(4)
OH1OS2OP2OS1OH4OS3
ObjectiveOS1 Fire Safety
Attribution
[F20,F22-OS1.2] Applies to assemblies required to provide fire resistance.
Application
Application 1: 
Minimum extension of anchors connecting parallel roof or floor joists to above-ground masonry walls to provide the required lateral support, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • where the wall height above the foundation wall does not exceed 11 m, and
  • in which the roof or floor system above the first storey is not of concrete construction.
Exceptions: 
except:
  • where floor joists are located not more than 1 m above grade where the lateral load on the wall will be less than it would be if the joists were located at a point higher up the wall [see Sentence 9.20.11.1.(1)], and
  • as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry is designed for specified loads on the basis of ultimate and serviceability limit states.
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate strength of floor or roof joists to resist lateral loads, which could lead to inadequate anchorage of floor or roof assemblies to masonry walls, which could lead to inadequate lateral stiffness, which could lead to an inability to resist lateral loads or inadequate distribution of gravity loads, which could lead to cracking or buckling.
Where masonry construction is required to provide fire resistance, this is to limit the probability of compromised fire resistance of the assembly, which could lead to harm to persons.