This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.20.11.2.(2) | Application | Intent |
OH1 | OS2 | OP2 | OS1 | OH4 | OS3 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Bonding of transverse masonry walls providing lateral
support to above-ground masonry walls, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]:
Exceptions:
except as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry
is designed for specified loads on the basis of ultimate and serviceability
limit states.
|
Top of Page | |
Intent | Intent 1: To limit the probability of:
This is to limit the probability of failure
of connections between intersecting walls under lateral loads, which could
lead to an inability to transfer lateral loads from masonry walls to intersecting
walls intended to provide lateral support, which could lead to inadequate
lateral stiffness, which could lead to an inability to resist lateral loads
or inadequate distribution of gravity loads, which could lead to cracking
or buckling.
This is to limit the probability of compromised structural integrity,
which could lead to:
This is to limit the probability of harm to persons.
|
Top of Page |