Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.20.11.6.(1) | Application | Intent |
OS2 | OP2 | OH1 | OH4 | OS3 | OS1 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Masonry piers with anchor bolts installed in their
tops, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
Exceptions:
except as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry
is designed for specified loads on the basis of ultimate and serviceability
limit states.
|
Top of Page | |
Intent | Intent 1: To limit the probability of insufficient depth of concrete
or masonry for an adequate bond with anchor bolts, which could lead to inadequate
withdrawal resistance, which could lead to an inability to resist expected
wind loads, which could lead to overturning, lifting, sliding or excessive
deflection of the superstructure. This is to limit the
probability of compromised structural integrity, which could lead to:
This is to limit the probability of harm to persons.
Intent 2: To direct Code users to Sentence 9.15.2.3.(4), which
contains requirements for piers. |