Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.20.13.3.(1)
OS2OP2OH1
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Locations where flashing is to be installed in masonry and masonry veneer walls, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • where the wall height above the foundation wall does not exceed 11 m, and
  • in which the roof or floor system above the first storey is not of concrete construction.
Exceptions: 
except as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry is designed for specified loads on the basis of ultimate and serviceability limit states.
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate protection from precipitation at vulnerable locations in masonry and masonry veneer walls, which could lead to precipitation or meltwater ingress.
This is to limit the probability of:
  • the deterioration of masonry due to freeze-thaw stresses, which could lead to masonry falling, or
  • the deterioration of elements inboard of the masonry, which could lead to compromised structural integrity, which could lead to structural collapse.
This is to limit the probability of harm to persons.