Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.20.13.6.(3)
OH1OS2OP2OS1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Location of flashing beneath weep holes in masonry veneer over wood-frame walls sheathed with a sheathing membrane, a non-wood-based rigid exterior insulating sheathing or a semi-rigid insulating sheathing with an integral sheathing membrane, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • where the wall height above the foundation wall does not exceed 11 m, and
  • in which the roof or floor system above the first storey is not of concrete construction.
Exceptions: 
except as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry is designed for specified loads on the basis of ultimate and serviceability limit states.
Top of Page
Intent
Intent 1: 
To limit the probability of water running down the face of the sheathing membrane or insulating sheathing, which could lead to water entering the backing assembly.
This is to limit the probability of compromised thermal performance of components intended to resist heat transfer, which could lead to:
  • an inadequate control of temperatures in interior spaces, relative humidity or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to further compromised integrity of environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.