Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.20.13.9.(1)
OH1OS2OP2
ObjectiveOP2 Structural Sufficiency of the Building
Attribution
Application
Application 1: 
Protection of the interior finish of exterior masonry walls where it is of a type that may be damaged by moisture, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • not exceeding 11 m in height above the foundation wall, and
  • in which the roof or floor system above the first storey is not of concrete construction.
Exceptions: 
except:
  • for cavity walls,
  • for walls that are protected for their full height by the roof of a carport or porch,
  • as stated in Sentence 9.20.13.9.(3), which applies to walls where the finish is protected by insulation that effectively limits the passage of water and is applied by a waterproof adhesive or mortar directly to parged masonry, and
  • as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry is designed for specified loads on the basis of ultimate and serviceability limit states.
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate moisture protection of interior finishes, which could lead to rainwater penetrating the interior surface of solid masonry walls and contacting vulnerable interior finishes.
This is to limit the probability of the deterioration of elements inboard of the masonry, which could lead to compromised structural integrity, which could lead to structural collapse, which could lead to damage to the building.