Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.21.3.1.(1)
OS2OH1OS1OS3OP1
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Liner materials for rectangular masonry or concrete chimneys that are not more than 12 m in height and that serve fireplaces or appliances having a combined total rated heat output of 120 kW or less, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to rectangular masonry or concrete chimneys, in buildings to which Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6], as stated in Sentence 6.3.1.2.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that the direct exposure of chimney components to corrosive flue gases and condensates, and extreme fluctuations in temperature, will lead to the premature failure of chimney liners, which could lead to the spillage of combustion products, which could lead to the leakage of carbon monoxide gas into living space, which could lead to the acute poisoning or asphyxiation of persons.
Top of Page