Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.22.2.2.(3) | Application | Intent |
OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Offsetting of joints between firebrick liners and
adjacent backing masonry, for masonry fireplaces constructed on-site, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]. Application 2: This also applies to fireplaces in buildings to
which Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application
of Part 6], as stated in Sentence 6.2.1.5.(1). |
Top of Page | |
Intent | Intent 1: To limit the probability that corresponding cracks in firebrick
liner units and backing masonry units will provide a path for the flow of
flames or radiant heat, which could lead to the ignition of combustible building
components, which could lead to damage to the building. |