Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.22.5.2.(1)
OS1OS2OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Support of fire chamber floors and hearths for masonry fireplaces constructed on-site, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.22.5.2.(2), which applies to hearths for fireplaces with an opening raised not less than 200 mm from a combustible floor.
Application 2: 
This also applies to fireplaces in buildings to which Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6], as stated in Sentence 6.2.1.5.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that an insufficient mass of concrete will lead to excessive heat transfer by conduction through the fire chamber floor or by radiation from the fireplace opening, which could lead to the ignition of combustible building components, which could lead to harm to persons.
Top of Page