Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.22.5.2.(2)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Hearths for masonry fireplaces constructed on-site whose opening is raised not less than 200 mm from a combustible floor, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to fireplaces in buildings to which Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6], as stated in Sentence 6.2.1.5.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that heat radiating from the fireplace opening to a hearth that rests directly on a combustible floor will raise the hearth temperature excessively, which could lead to the ignition of combustible building components, which could lead to harm to persons.
Intent 2: 
To exempt certain fireplaces from the application of Sentence 9.22.5.2.(1), where the fireplace opening is raised sufficiently above a combustible floor to reduce the risk of raising the hearth temperature excessively.
Top of Page