Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.22.9.2.(1) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Clearance of metal exposed to the interior of masonry
fireplaces that also penetrates through the face of the fireplace, in masonry
fireplaces constructed on-site, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]. Application 2: This also applies to fireplaces in buildings to
which Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application
of Part 6], as stated in Sentence 6.2.1.5.(1). |
Top of Page | |
Intent | Intent 1: To limit the probability that the conduction of excessive
heat through metal fireplace components will lead to the ignition of combustible
building components, which could lead to harm to persons. |