Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.3.5.(2)
OS2OP2OH1OH4OS1OS3
ObjectiveOS1 Fire Safety
Attribution
[F20,F22-OS1.2] Applies to assemblies required to provide fire resistance.
Application
Application 1: 
Minimum dimensions and orientation of staples used to fasten roof or wall sheathing or subflooring, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate diameter, thickness or crown length, or incorrect orientation, of staples, which could lead to inadequate capacity, rigidity or pull-through resistance, which could lead to an inability to resist expected lateral, gravity or wind-uplift loads.
Where assemblies are required to provide fire resistance, this is to limit the probability of compromised fire resistance of the assembly, which could lead to harm to persons.
Top of Page