Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.23.3.5.(3) | Application | Intent |
OS2 | OP2 | OH1 | OH4 | OS1 | OS3 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Minimum shank and head diameter of roofing nails used
to fasten fibreboard or gypsum sheathing to framing members, in wood-frame
constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
|
Top of Page | |
Intent | Intent 1: To limit the probability of an inadequate nail diameter
or head size, which could lead to inadequate capacity, rigidity or pull-through
resistance, which could lead to an inability to resist expected lateral, gravity
or wind-uplift loads. Where wood-frame construction supports
or is part of an environmental separator, this is to limit the probability
of the displacement or failure of required environmental separation elements,
which could lead to:
This is to limit the probability of:
This is to limit the probability of:
This is to limit the probability of harm to persons.
|