Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.23.5.5.(1) | Application | Intent |
OS2 | OP2 | OH1 | OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Notching, drilling or otherwise weakening wood roof
trusses, in wood-frame constructions to which Section 9.23. applies
[see Sentence 9.23.1.1.(1) for application of Section 9.23.].
|
Top of Page | |
Intent | Intent 1: To limit the probability of an overly reduced cross-section,
which could lead to an inability to resist expected gravity and lateral loads,
which could lead to excessive movement or deformation, or bending or buckling
failure, which could lead to excessive deflection and damage to roofing.
Where assemblies are required to provide fire resistance, this is
to limit the probability of compromised fire resistance of the assembly, which
could lead to harm to persons.
|
Top of Page |