Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.9.6.(1)
OS2OP2OH1OH4OS1OS3
ObjectiveOS2 Structural Safety
Attribution
[F20,F22-OS2.3] Applies to elements that support or are part of an environmental separator.
Application
Application 1: 
Doubling of trimmer joists spanning more than 0.8 m, but less than 2 m [see Sentence 9.23.9.6.(2)], around floor openings, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate strength and stiffness, which could lead to an inability to resist expected dead and live gravity loads transferred from long header joists.
This is to limit the probability of compromised structural integrity, which could lead to:
  • the structural collapse of wood-frame construction, or
  • for exterior floors or floors supporting environmental separators, the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to further compromised structural integrity.
This is to limit the probability of harm to persons.
Top of Page