Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.10.1.(1)
OS2OP2OH1OH4OS1OS3
ObjectiveOH4 Vibration and Deflection Limitation
Attribution
[F22-OH4] Applies to floors and elements that support floors.
Application
Application 1: 
Minimum size and spacing of loadbearing and non-loadbearing wall studs, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate cross-sectional area or excessive slenderness, which could lead to an inability to resist expected gravity and lateral loads, which could lead to excessive deflection or failure.
For floors and constructions supporting floors, this is to limit the probability of:
  • compromised structural integrity, or
  • for exterior floors or environmental separators supporting a floor, the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to further compromised structural integrity.
This is to limit the probability of excessive movement, vibration or deflection of floors, which could lead to negative effects on the psychological well-being of persons.