Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.10.3.(2)
+
Application
Application 1: 
Orientation of wall studs in gable ends of roofs that contain only unfinished space, or in non-loadbearing interior walls where the minimum stud size, maximum stud spacing, and maximum unsupported stud height do not exceed the limits stated in Table 9.23.10.1., in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To modify the application of Sentence 9.23.10.3.(1) and allow studs to be installed 'on the flat' in constructions where the studs are subject to limited gravity and lateral loads.