Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.11.2.(1)
OS2OP2OH1OH4OS1OS3
ObjectiveOS1 Fire Safety
Attribution
[F20,F22-OS1.2] Applies to assemblies required to provide fire resistance.
Application
Application 1: 
Provision of bottom wall plates, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of:
  • inadequate distribution of vertical loads to and from studs,
  • inadequate lateral support for the ends of the studs, or
  • inadequate diaphragm action of plates.
This is to limit the probability of the excessive deflection of walls.
Where assemblies are required to provide fire resistance, this is to limit the probability of compromised fire resistance of the assembly, which could lead to harm to persons.