Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.11.2.(2)
OS2OP2OH1OH4OS1OS3
ObjectiveOS3 Safety in Use
Attribution
[F22-OS3.1] Applies to floors and elements that support floors.
[F22-OS3.7] Applies to walls, and elements that support walls, that contain doors or windows required for emergency egress.
Application
Application 1: 
Maximum projection, over supports, of bottom wall plates in exterior walls, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate bearing and fastening dimensions between walls and their supports, and eccentricity between load and support, which could lead to an inability to resist expected gravity and lateral loads, which could lead to:
  • the inadequate distribution of vertical loads to and from studs, which could lead to the excessive deflection of wall plates and walls, or
  • inadequate diaphragm action of plates, which could lead to the excessive deflection of walls.
Where walls support floors, this is to limit the probability of:
  • the excessive deformation of floors, which could lead to compromised operation of doors required for egress in an emergency, or
  • the excessive deflection or vibration of floors, which could lead to persons losing their balance, tripping or falling.
This is to limit the probability of harm to persons.
Top of Page