Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.11.3.(1)
OS2OP2OH1OH4OS1OS3
ObjectiveOS2 Structural Safety
Attribution
[F20,F22-OS2.3] Applies to elements that support or are part of an environmental separator.
Application
Application 1: 
Minimum number of top wall plates in loadbearing stud walls, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Exceptions: 
except as stated in Sentences 9.23.11.3.(2) to (4), which apply where studs are directly beneath the supported framing above, or where lintels provide the required support.
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate capacity to transfer loads from supported floor and roof framing members, which could lead to an inability to resist expected gravity and lateral loads, which could lead to:
  • the inadequate distribution of vertical loads to and from studs, which could lead to the excessive deflection of wall plates, or
  • inadequate diaphragm action of plates, which could lead to the excessive deflection of walls.
This is to limit the probability of compromised structural integrity, which could lead to:
  • the structural collapse of wood-frame construction, or
  • where wood-frame construction supports or is part of an environmental separator, the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to further compromised structural integrity.
This is to limit the probability of harm to persons.