Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.11.4.(2)
OS2OP2OH1OH4OS1OS3
ObjectiveOS1 Fire Safety
Attribution
[F20,F22-OS1.2] Applies to assemblies required to provide fire resistance.
Application
Application 1: 
Tying of double top plates at corners and intersections of loadbearing stud walls, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate connection between wall assemblies that provide transverse support, which could lead to an inability to resist expected lateral loads, which could lead to the excessive deflection or failure of walls.
Where assemblies are required to provide fire resistance, this is to limit the probability of compromised fire resistance of the assembly, which could lead to harm to persons.
Intent 2: 
To provide a cross-reference to Sentence 9.23.11.4.(4) and thereby further define its application.
Top of Page