Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.13.7.(4)
OS2OP2OH1OS1
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Minimum dimensions and installation of struts acting as intermediate support for lumber roof joists and rafters, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability that struts will be unable to transfer compressive roof loads to loadbearing walls, which could lead to inadequate intermediate support for rafters or roof joists.
This is to limit the probability of compromised structural integrity, which could lead to:
  • the structural collapse of wood-frame construction,
  • where roof and ceiling framing members support required elements of environmental separators, the excessive deformation, displacement or failure of these elements, which could lead to deterioration, which could lead to further compromised structural integrity of roofs or environmental separators, or
  • where roof and ceiling framing members support assemblies exposed to the exterior, excessive water ingress, which could lead to deterioration.
This is to limit the probability of harm to persons.
Top of Page