Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.13.8.(2)
+
Application
Application 1: 
Minimum sizes and maximum spans of ridge beams supporting roof rafters and joists, where such rafters and joists are not longer than 4.9 m and where the roof does not support concentrated loads, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Exceptions: 
except as stated in Sentence 9.23.13.8.(3), which applies to ridge beams where the beams are:
  • not less than 38 mm by 140 mm, and
  • adequately supported at intervals not exceeding 1.2 m.
Top of Page
Intent
Intent 1: 
To limit the application of Sentence 9.23.4.2.(4).