Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.13.9.(1)
OS2OP2OH1OS1
ObjectiveOS1 Fire Safety
Attribution
[F20,F22-OS1.2] Applies to assemblies required to provide fire resistance.
Application
Application 1: 
Acceptable methods for restraining the bottom edges of lumber roof joists supporting ceiling material other than structural sheathing, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability that low-strength interior finishes will be relied on to provide lateral restraint, which could lead to an inability to resist expected gravity or lateral loads or shrinkage stresses due to drying, which could lead to joists twisting, which could lead to failure of the ceiling.
Where assemblies are required to provide fire resistance, this is to limit the probability of compromised fire resistance of the assembly, which could lead to harm to persons.
Top of Page